Skip to main content
X12 - 625 - Well Information
Skylar Nguyen avatar
Written by Skylar Nguyen
Updated over 2 weeks ago

Product: X12 EDI

Transaction: 625


FUNCTIONAL GROUP=WL

FUNCTIONAL GROUP=

This X12 Transaction Set contains the format and establishes the data content of the Well Information Transaction Set (625) for use within the context of an Electronic Data Interchange (EDI) environment. The transaction set facilitates the exchange of engineering, geological and environmental information related to non-financial well activities. The transaction set can be used between private industry trading partners to relay information about joint venture well activities or between private industry and government agencies.
This transaction set shall not be used to relay financial information such as regulatory royalty payment information or costs associated with well activities.


SCHEMA


ST

Segment

Name

Position

ST

0100

BGN

Beginning Segment

0200

HL

Segment

Name

Position

HL

0300

PID

0400

DTP

Date or Time or Period

0500

REF

0600

YNQ

Yes/No Question

0700

MTX

0800

LIE

Segment

Name

Position

LIE

Individual or Event Location

0900

PPA

Property Location

1000

MEA

1100

CID

Segment

Name

Position

CID

Characteristic/Class ID

1200

QTY

1300

MEA

1400

N1

LM

Segment

Name

Position

LM

Code Source Information

2000

LQ

Industry Code Identification

2100

SE

Transaction Set Trailer

2200


COMMENTS


Notes

1/0300

The HL segment identifies the appropriate level: Report, Contract, Operating Unit, Ancillary Facility, Well, Wellbore, and Well Completion.

1/0400

The PID segment, when used, identifies a component and its accompanying description if needed, for the associated hierarchical level.

1/0700

The YNQ segment provides responses to conditions relevant to the associated hierarchical level.

1/0900

The LIE Loop is used to provide physical location information related to the associated hierarchical level.

1/1000

The PPA segment is used to relay descriptive information about a location.

1/1100

The MEA segment shall only be used to relay measurement information (e.g., 660 feet from section line) associated with a physical location.

1/1200

The CID Loop shall only be used to identify non-location related attributes (e.g., the evaporation rate, the number of producing wells, blowout preventor test pressure measurement) of the associated hierarchical level or a component of the hierarchical level.

1/1300

The QTY segment is used to relay quantities or counts associated with the physical characteristics of a well.

1/1400

The MEA segment shall only be used to relay any physical measurements related to the physical characteristics of a well.

rev 05/12/2024

Did this answer your question?